A chemical formulation of QuantiShield  (Surtreat  TPS II) is applied  to the surface of concrete and migrates to the rebar surface and inhibited rebar corrosion by stabilizing rebar corrosion resistant surface, reducing cement porosity and the water soluble chloride content.  The powerful anodic site functioning corrosion inhibitor has reduced the corrosion hot spots by a greater degree than the average rate.

 

Rebar corrosion rates measured using the GalvaPlus Instrument which measures corrosion current via polarization resistance in micro-amps per cm2 (uA/cm2)

which is converted into micrometer  of steel lost per year.   Measurements are made at 30 points on surface.

QuantiSHIELD TPS II

DESCRIPTION

QuantiSHIELD SURTREAT TPS II is a multi phase, inorganic, surface applied corrosion inhibitor for use on typical (3000-5000 psi), hardened concrete. It will protect reinforcing steel in concrete from corrosion on multiple fronts by penetrating the concrete surface and migrating to the steel. TPS II forms a passivating film on the steel surface which provides protection from the corrosion process, thereby  extending the service life of the structure.

 

FEATURES/ADVANTAGES/BENEFITS

•      Outstanding one part corrosion inhibitor           for hardened steel reinforced concretes-           old and new.

•      Proven laboratory  and site performance

•      Simple to use

•      Can be applied to a variety of surfaces

•      Environmentally friendly

•      Breathable

•      Extremely durable

•      Penetrates easily

•      Can not be peeled or scratched off

•      Can be painted,coated,or overplayed as           needed

 

SPECIAL FEATURES

QuantiSHIELD SURTREAT TPS II functions on multiple fronts to deliver superior performance. In addition to creating a passivating film on the surface of the imbedded reinforcement QuantiSHIELD SURTREAT TPS II inhibits and prevents corrosion by increasing electrical resistance, complexing and removing water-soluble chlorides, re alkalizing areas of carbonation, stopping water penetration and diffusion. In addition Quantishield SURTREAT TPS II has been shown to improve substrates strength.

 

WHERETO USE

Reinforced, precast, prestressed, or post-tensioned  concrete structures.

To date QuantiSHIELD SURTREAT TPS II has successfully been used on bridges, roadways, runways, various buildings including stadiums, condominiums and office, parking garages, marine structures, industrial plants including food